Checkline DT-209X Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Instrumentos de medición Checkline DT-209X. Checkline DT-209X User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 2

6FULL Full memory indicator (the unit cannot store additional data) CCCCC Clear data from memory. Holding memory button for 5 seconds will clear s

Pagina 3 - Table of Contents

7 Measurement Mode The Measurement Mode is changed with the Measurement Mode Selector switch. There are three basic settings USB, Standard and

Pagina 4

8Average mode • The max, min, average, last and time of measurement can be stored in memory via power button. • The unit can store a maximum of 30

Pagina 5

9Average Mode USB Mode Online measurements, software controlled programs can run and take measurements while the

Pagina 6 - Measurement

10Measuring Methods Rotational speed measurement (Contact RPM) Example: RPM measurement using the cone tip for motor rotation. The contact adapt

Pagina 7 - Rotation Speed

11Three decimal points will flash on the center of the display when the tachometer is out of range. Speed and Length Measurements Example: Length me

Pagina 8 - For rotational

12Typical measurement update is 1 second. (Using the software the update time can be adjusted as fast as 0.5 second). Things to Remember The rub

Pagina 9

13 CAUTION: Do not look into the laser beam opening while in operation. Staring into the laser beam can result to eye damage. The power switch i

Pagina 10 - rEAdy

14 Pressing the Power Switch it will show the memory block number where readings will be stored. The block number will flash for a few seconds. (Me

Pagina 11

15The memory location where the measurement will be stored is shown on the Unit and Measurement section of the LCD display. (“M” followed by the num

Pagina 12

Thank you for your purchase of this Tachometer Product. This manual explains how to operate your equipment safely and correctly. The manual covers

Pagina 13

162. Average Mode Average mode is displayed on the LCD screen Pushing the Power Switch will show the memory block number where reading

Pagina 14

17 Releasing the Power Switch will trigger the auto shut off feature to activate. 3. USB Mode The Measurement Mode Selector Switch is set

Pagina 15

18 To recall memory from the DT-209X, the memory button is pressed and then released. The last measured value is displayed. The Memory Button

Pagina 16

19The stored data in the tachometer can be recalled each time the memory button is pressed (M1→M2 etc.). (This is only applicable to the last Memory

Pagina 17

20 The Memory Button is pressed and then released. The minimum measured value is displayed. The memory button is pressed and then released.

Pagina 18

21 Clearing all the stored memory blocks requires manual deletion from the tachometer. (Example: To clear 23 blocks of memory requires erasing th

Pagina 19

22LO BAT Maximum Values Allowed Unit Full range Unit Full range Non contact RPM 99,999 Contact RPM 25,000 m/min 3810.0 yd/min 4617.0 ft/min 12,50

Pagina 20

23Specifications Content Model DT-209X (6-inch cir wheel), DT-209X-S12 (12-inch cir wheel) Standard mode Measurement with memory switch Average m

Pagina 23

DT-209X Handheld Digital Laser Tachometer Table of Contents Section I – Handheld Tachometer • Description of Parts………………………………………………………………………….

Pagina 25

DT-209X API Section Thank you for your purchase of the DT-209X handheld tachometer. Please read this section carefully before using the DT-209X soft

Pagina 26 - 9999.9

Observe caution when using this software and mounting the tachometer. Serious damage to equipment is possible when misused. DT-209X API Manual CD

Pagina 27

DT-209X USB Driver Installation: (WINDOWS XP) Included in your package is a USB cable. Attach USB cable to the handheld tachometer and host computer a

Pagina 28

Click next. Installation process will continue. After installation is completed the following window will be displayed. Cl

Pagina 29

Browse the CD content. Go to PC_API folder Windows installer package Select Windows installer package to

Pagina 30

DT-209X set up wizard will open. Click “Next>” Choose installation folder where DT-209X program will be stored. 32

Pagina 31

Disk Cost Space availability. Browse • Allows users to select location of the application • Default set up: C: \Program Files\NIDEC-SHIMPO\DT-20

Pagina 32

Set up wizard will start the installation process. Please allow a few minutes to complete the installation process.

Pagina 33

DT-209X Application Software Read this section carefully as it holds important information regarding the DT-209X software and mode windows operation

Pagina 35

Main Screen Description 1. Exit – terminates the program and exits the software 2. USB Mode – Online measurement (Note: Make sure that the DT

Pagina 36

5. Time Synchronize - Synchronize time with host computer for generating time stamping reports. To activate this feature click on time synchronize

Pagina 37

Example: In Non-contact RPM Maximum expected speed is 1,000 RPM. Entering 1,000 in the programmable analog output will scale 1V from 0 to 1000 rpm.

Pagina 38

Virtual Software LCD Display Troubleshooting USB Communication • If USB communication cannot be establish check USB cable from the tachomete

Pagina 39 - DT209X for PC Windows.lnk

Unit Selector (Software) Selecting units of measure can be changed easily from the software. Provided on the main window is a virtual copy of the

Pagina 40

USB Mode Screen USB mode screen display explanation Make sure that the DT-209X handheld tachometer is set to USB mode on the selector switch. Any

Pagina 41

Files are saved in CSV format, which can be opened by spreadsheets. Sample of data opened in Microsoft Excel (USB Mode). Example: T

Pagina 42

Sample of data saved in Excel (Standard Mode). 3. Restore – file retrieval button. Open saved file fro

Pagina 43

File restore window The letter “R” identifies file restored on the list of data shown from the screen. 4. Start - measurement st

Pagina 44

5. Print – Print function from the software allows transfer of images displayed from the screen to a local printer. Keystroke shortcut “ALT + P”. 6

Pagina 45

1 Model DT-209X casing is similar to standard DT-207/DT-205L with addition of USB port, analog output, and selector switch. DT-209X Part

Pagina 46

Confirmation screen, indicating unselected data will be erased 9. Graph – Opens graph in another window, only available in USB mode.

Pagina 47

Example: The start trigger is set to 10,000. The tachometer will only start recording values when measurements exceed 10,000.

Pagina 48

13. Maximum, Minimum, and Mean Value – The maximum, minimum and mean value are displayed based from the recorded data on the table.

Pagina 49

15. Start and End – Displays the beginning and the end of measurements. Format: Month/ Day/ Year Time based on 24 Hours: Hour/Min/Seconds

Pagina 50

18. Time – Displays synchronized time from the host computer. Format: Month/Day/Year followed by Time: Hour/Minutes Before testing it is adv

Pagina 51

USB Mode Graph Screen This section describes the parts and functions of the Graph Screen under USB mode. 10 987654321 1. Cl

Pagina 52

4. All – horizontal display control, time axis. Setting Explanation All It automatically sets time present while the measurements are in progres

Pagina 53

Standard Mode Screen Explanation of the Standard mode screen: In this mode data can be downloaded from the DT-209X memory. Memory tab separates ea

Pagina 54

1. Main – returns to the main screen (Shortcut keystroke ALT + M). 2. File Save – Downloaded data from the DT-209X is saved in CSV format. (Shortcu

Pagina 55

55is selected the stored data from the DT-209X is cleared. No eval of previously stored data is possible. Selecting Cancel exits evice memory function

Pagina 56

2 Parts Function 1 USB Connector Mini-USB connector for PC online measurements and data downloads. 2 Analog Output Connector 0 to 1-volt analog outp

Pagina 57

7. Measurement Data – measured values stored in each memory block is displayed. 8. Block Tab – Memory block separation. Each tab corresponds to a

Pagina 58

Average Mode Screen verage mode screen description and explanation. Average Mode screen initial window prior to download A Average Mode

Pagina 59

1. Main – returns to the main screen. (Shortcut Keystroke ALT + M) 2. File Save – Saves downloaded data from the tachometer. File save button is ina

Pagina 60

Restore File Window 4. Download – download saved data from the DT-209X. All blocks are displayed based from their occurrence. (Keystroke

Pagina 61

Once “OK” is s 7. ata ane begi changes ased ormat H 8. ax, Min, A elected from the list. elected, all the Av

Pagina 62

9. Blocks – Displays number of memory blocks downloaded from the tachometer. 10. HH:MM:SS. time when the data is accessed from the tachometer.

Pagina 63

62 Display Hold: This feature is an enhancement to the DT-209X software, designed for users hich requires the ability to limit the amount of time the

Pagina 64

ooting SectionTroublesh Problems Solution Software would not start, “Start” button anCheck mode selector switcd “Download” h. Set to USB MODE.

Pagina 65

Measured value is divided by 2 There are two versions of the DT-209X, Standard Version DT-209X is set for 6 inch circumference wheel, and DT-209X-S12

Pagina 66

3 Non-Contact Rotation Speed Measurement RPM Non- USB Mode(No cable connected) ON and OFF switch and block separator. For standard and average m

Pagina 67

4Unit Selector Switch Multi-mode capability measures RPM, mPM, YPM, FPM, IPM and total meters, yards, feet and inches. NOTE: Select

Pagina 68

5 Operation • The switch selector can be turned clockwise or counter-clockwise depending on which unit of measure is required. • The unit of measu

Comentarios a estos manuales

Sin comentarios