TABLE OF CONTENTS
01.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 02
02.0 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03
2.1 Gauge
2.2 Complete Kit
03.0 Operating Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 04
3.1 The Keypad
3.2 The Display
3.3 The Transducer
04.0 Condition and Preparation of Measuring Surface . . . . . . . . . . . . . . . . . . 07
05.0 Zeroing The Probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 08
0 6.0 Calibration Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 09
6.1 Programming The Sound Velocity
07.0 Transducer Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
008.0 Taking Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
09.0 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
10.0 Appendix A, Applications Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
11.0 Appendix B, Sound Velocity Of Common Materials . . . . . . . . . . . . . . . 16
12.0 Material Safety Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
13.0 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
IMPORTANT NOTE:
Inherent in ultrasonic thickness measurement is the possibility that the
instrument will use the second rather than the first echo from the back
surface of the material being measured. This may result in a thickness
reading that is TWICE what it should be. Responsibility for proper use of
the instrument and recognition of this phenomenon rests solely with the
user of the instrument.
NOTES
Vista de pagina 0
1 2 3 4 5 6 ... 10 11

Indice de contenidos

Pagina 1 - TABLE OF CONTENTS

– 1 –– 20 –TABLE OF CONTENTS01.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0202.0

Pagina 2 - 1.0 INTRODUCTION

– 10 –7.0 TRANSDUCER SELECTIONThe TI-25P is inherently capable of performing measurements on a wide range ofmaterials, from various metals to glass an

Pagina 3 - 13.0 WARRANTY

TI-25PULTRASONICTHICKNESS GAUGEOperating InstructionsCHECK•LINE®BY ELECTROMATICELECTROMATIC E Q U I P M E N T C O., I N C.600 Oakland Ave., Cedarhurs

Pagina 4 - 3.0 OPERATING ELEMENTS

– 2 –1.0 INTRODUCTIONThe TI-25P is a precision Ultrasonic Micrometer. Based on the same operatingprinciples as SONAR, the TI-25P is capable of measuri

Pagina 5 - 1.8.8.8.8

– 3 –2.0 OVERVIEW2.1 Gauge– 18 –13.0 WARRANTYELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to theoriginal purchaser that this product is of

Pagina 6

– 4 –3.0 OPERATING ELEMENTSThe TI-25P interacts with the operator through the membrane keypad and theLCD display. The functions of the various keys on

Pagina 7 - PPENDIX A: APPLICATION NOTES

– 5 –3.2 The DisplayNumerals: The numeric portion of thedisplay consists of 4 complete digitspreceded by a leading "1", and is usedto displa

Pagina 8 - 9.0 SPECIFICATIONS

– 6 –M Symbol: When the M symbol is on,in conjunction with the /s symbol, theTI-25P is displaying a sound-velocityvalue in meters-per-second.3.3 The T

Pagina 9 - 8.0 TAKING MEASUREMENTS

– 7 –4.0 CONDITION AND PREPARATION OF MEASURING SURFACEIn any ultrasonic measurement scenario, the shape and roughness of the test surface are of para

Pagina 10 - 7.0 TRANSDUCER SELECTION

– 8 –5.0 ZEROING THE PROBESetting the Zero Point of the TI-25P is important for the same reason that settingthe zero on a mechanical micrometer is imp

Pagina 11 - THICKNESS GAUGE

– 9 –6.0 CALIBRATION PROCEDUREIn order for the TI-25P to make accurate measurements, it must be set to the cor-rect sound-velocity for the material be