3
3.0 OPERATING PROCEDURE
3.1 Inserting the material to be measured
Carefully thread the material to be measured through the measuring roller
and roller guides, as shown below. It is important to ensure that the measured
material runs smoothly through the roller.
To avoid damage do not move the center roller by hand
using force.
3.2 Setting the Maximum Tension Detector (optional)
Need copy?
Are there any other steps that need to be taken
before the gauge begins operating?
6
6.0 SPECIFICATIONS
Calibration According to factory procedure
Accuracy ± 1% full scale (FS) or ± 1 graduation on scale
Scale diameter 2.28 in (58mm)
Temperature range 50 to 113 °F (10 to 45 °C)
Air humidity 85% RH, max.
Housing material Chill-cast aluminum
Housing dimensions 3.1 in x 2.45 in x 1.1 in (78 x 62 x 27 mm) — L x W x H
Weight approx. 0.7 lbs. (300g)
7.0 TENSION RANGES/CALIBRATION MATERIAL
Model Range (grams) Calibration Material*
ODT-10 2-10 Faden: 25 tex
ODT-20 2-20 Faden: 25 tex
ODT-30 3-30 Faden: 25 tex
ODT-50 5-50 PA 0.12mm Ø
ODT-70 10-70 PA 0.12mm Ø
ODT-100 10-100 PA 0.12mm Ø
ODT-200 20-200 PA 0.20mm Ø
ODT-300 20-300 PA 0.20mm Ø
ODT-400 40-400 PA 0.20mm Ø
ODT-500 50-500 PA 0.20mm Ø
ODT-800 20-800 PA 0.20mm Ø
ODT-1K 50-1000 grams PA 0.30mm Ø
* Suitable for 95% of applications. PA = Polyamide Monofilament. If the material
to be measured differs significantly from the factory calibration material in diameter,
rigidity, shape, etc., we recommend calibration using customer material. For this
purpose, a material sample of about 5 m should be supplied. International unit for
tension force: 1 cN = 1.02 g = 0.01 N